Aligned Abernathy: Built for Scale in Northwest Texas

High-capacity infrastructure for AI and cloud workloads, backed by dedicated power and long-term regional investment.

STRATEGY

Why Choose Aligned Data Centers in Abernathy, TX

Located in Hale County near Abernathy, the Caprock campus brings large-scale data center capacity to a region where long-term growth and resource stewardship go hand in hand. With a closed-loop cooling design that protects local water resources and a development approach aligned with regional priorities, the campus supports both advanced compute and the communities around it.

consistency icon

Dedicated Power Infrastructure

Aligned is building dedicated infrastructure to deliver reliable, scalable power without impacting local ratepayers.

consistency icon

Local Investment and Economic Impact

The Caprock campus supports jobs, local vendors, and long-term tax revenue in Hale County.

data centers

AI-Ready Data Centers in Abernathy

Aligned’s flexible cooling technologies, customer-centric operations teams, and ultra-efficient infrastructure make Aligned Abernathy poised for continued growth. In addition to contributing to economic and job growth, we also invest in local community programs to create a lasting, positive impact for local residents. 

LBB-01

LBB-01 Data Center

  • 1498 County Road 315 Abernathy, Texas 79311

Campus Overview:

  • Bays with delivery platform and equipment trap  
  • Dedicated office and workspaces  
  • Shared conference rooms and drop-in office pods  
  • Secure storage 
  • 24x7x365 accessibility 
render of a data center campus aerial view
THE ALIGNED ADVANTAGE

What’s Inside

Engineered for speed, scale, and sustainability. 

power icon
Connectivity and Power

– 2 MW UPS line-ups
– N+1 block redundant topology
– 1MW Critical Distribution Panels (CDPs)
– 415V distribution to racks
– 100% Uptime SLA

cooling infrastructure icon aligned data centers
Cooling

– Delta³™ air cooling arrays in dedicated mechanical galleries
– Secondary loops with valves and taps for DeltaFlow~™ liquid cooling to support the highest-density GPU requirements
– Minimum N+1 redundancy
– Closed-loop chilled water system design

sustainability icon
Sustainability and Compliance

-100% renewable power
– Ultra-efficient cooling design
– Near-zero Water Utilization Efficiency (WUE) based on closed-loop chilled water system design
– eCarbon tracking
– Targeting carbon-neutral footprint by 2040
– Certified for SOC 2 Type 2, PCI DSS, HIPAA, HITECH, NIST 800-53, and ISO 27001

security icon
Security and Fire Protection

– 5-layer security approach
– 24x7x365 physical security staff onsite
– Fixed & PTZ cameras covering facility interior and exterior
– Very Early Smoke Detection Apparatus (VESDA)
– Dual interlocking pre-action zoned fire protection