Salt Lake City, UT
Why Salt Lake City?
For Salt Lake City metro area data center customers, Utah tax incentives can translate into significant savings, making the “Silicon Slopes” one of the lowest total cost of ownership markets in the U.S.
The Salt Lake City Metro Area is a growing technology hub with extensive connectivity options, cloud availability, attractive alternative energy incentives, and flexible infrastructure tax credits. In pro-business Utah, qualified data center customers are exempt from sales tax on purchases of data center equipment with an economic life of at least one year that is used in their operations.
The State of Utah also enjoys renewable energy sources such as solar and wind. Moreover, Utah is classified as a cold desert, and its low humidity levels enable data centers to employ ambient cooling, thus reducing cooling costs and total cost of ownership.
The state’s low occurrence of natural and man-made catastrophic events, among the lowest in the nation, is also a key decision point for Salt Lake metro area data center customers, especially as compared to West Coast and Pacific Northwest.
Salt Lake City also possesses a highly capable workforce.
SLC-01 Data Center
3333 W 9000 S, West Jordan, UT
- Renovated in 2018
- 55-acre campus
- Private, dedicated data center suites
- Concrete slab-on-grade and structured steel
- ASCE 7 occupancy category IV
- Wind importance factor of 1.15
- 24x7x365 accessibility
- Industry-leading PUE
- 5-layer security approach
- 24x7x365 physical security staff onsite
- Fixed & PTZ cameras covering facility interior and exterior
- Very Early Smoke Detection Apparatus (VESDA)
- Dual interlocking pre-action zoned fire protection
Connectivity
- Two diverse points of entry, per build
- Carrier-neutral
- On-net: Cogent, Comcast, FirstDigital Telecom, Lumen, PacketFabric, UTOPIA Fiber, Zayo, and Verizon
- Near-net: Comcast
- Four diverse meet-me rooms
Power
- 3 MW back-up generators
- 2 MW UPS line-ups
- N+1 block redundant topology
- 500 KVA PDUs
- 415V distribution to racks (A+B distribution)
- 100% renewable power
- Ultra-efficient cooling design
- Near-zero Water Utilization Efficiency (WUE) based on closed-loop chilled water system design
- eCarbon tracking
- Targeting carbon-neutral footprint by 2040
- Delta3™ air cooling arrays in dedicated mechanical galleries
- Secondary loops with valves and taps for DeltaFlow~ liquid cooling to support the highest-density GPU requirements
- Minimum N+1 redundancy
- Closed-loop chilled water system design Rooftop chillers
- System and Organization Control (SOC) 2 Type 2
- SOC 1 Type 2
- PCI DSS
- HIPAA
- HITECH
- NIST 800-53
- ISO 27001:2013
- Bays with delivery platform and equipment trap
- Dedicated office and workspaces
- Shared conference rooms and drop-in office pods
- Secure storage
SLC-02 Data Center
3333 W 9000 S, West Jordan, UT
- Completed in 2021
- Expandable to 60 MW
- Private, dedicated data center suites
- Two interconnected multi-tenant buildings
- ASCE 7 occupancy category IV data hall FM-120 and office FM-90 roof lift ratings
- Wind importance factor of 1.15
- 24x7x365 accessibility
- Concrete slab-on-grade and structured steel
- Industry-leading PUE
- 5-layer security approach
- 24x7x365 physical security staff onsite
- Fixed & PTZ cameras covering facility interior and exterior
- Very Early Smoke Detection Apparatus (VESDA)
- Dual interlocking pre-action zoned fire protection
Connectivity
- Two diverse points of entry, per build
- Carrier-neutral
- On-net: CenturyLink, Cogent, Comcast, FirstDigital Telecom, UTOPIA Fiber and Zayo
- Near-net: Comcast
- Four diverse meet-me rooms
Power
- 3 MW back-up generators
- 2 MW UPS line-ups
- N+1 block redundant topology
- 500 KVA PDUs
- 415V distribution to racks (A+B distribution)
- 100% renewable power
- Ultra-efficient cooling design
- Near-zero Water Utilization Efficiency (WUE) based on closed-loop chilled water system design
- eCarbon tracking
- Targeting carbon-neutral footprint by 2040
- Delta3™ air cooling arrays in dedicated mechanical galleries
- Secondary loops with valves and taps for DeltaFlow~ liquid cooling to support the highest-density GPU requirements
- Minimum N+1 redundancy
- Closed-loop chilled water system design
- Rooftop chillers
- System and Organization Control (SOC) 2 Type 2
- SOC 1 Type 2
- PCI DSS
- HIPAA
- HITECH
- NIST 800-53
- ISO 27001:2013
- Bays with delivery platform and equipment trap
- Dedicated office and workspaces
- Shared conference rooms and drop-in office pods
- Secure storage
SLC-03 Data Center
3333 W 9000 S, West Jordan, UT
- 5-layer security approach
- 24x7x365 physical security staff onsite
- Fixed & PTZ cameras covering facility interior and exterior
- Very Early Smoke Detection Apparatus (VESDA)
- Dual interlocking pre-action zoned fire protection
- Green Building Initiative (GBI) Green Globes® for New Construction certification – Three Green Globes®
- 100% renewable power
- Ultra-efficient cooling design
- Near-zero Water Utilization Efficiency (WUE) based on closed-loop chilled water system design
- eCarbon tracking
- Targeting carbon-neutral footprint by 2040
- Delta3™ air cooling arrays in dedicated mechanical galleries
- Secondary loops with valves and taps for DeltaFlow~ liquid cooling to support the highest-density GPU requirements
- Minimum N+1 redundancy
- Closed-loop chilled water system design
- Rooftop chillers
- System and Organization Control (SOC) 2 Type 2
- SOC 1 Type 2
- PCI DSS
- HIPAA
- HITECH
- NIST 800-53
- ISO 27001:2013
- Bays with delivery platform and equipment trap
- Dedicated office and workspaces
- Shared conference rooms and drop-in office pods
- Secure storage
SLC-04 Data Center
3333 W 9000, S West Jordan, UT
- Impasse steel security fencing with laser intrusion detection
- Five-layer security design; motorized gates
- Card reader access
- 24x7x365 on-site security guards
- Multiple checkpoints: mantraps, dual authentication (biometrics)
- 100% renewable power
- Ultra-efficient cooling design
- Near-zero Water Utilization Efficiency (WUE) based on closed-loop chilled water system design
- eCarbon tracking
- Targeting carbon-neutral footprint by 2040
- Delta3™ air cooling arrays in dedicated mechanical galleries
- Secondary loops with valves and taps for DeltaFlow~ liquid cooling to support the highest-density GPU requirements
- Minimum N+1 redundancy
- Closed-loop chilled water system design
- Rooftop chillers
- System and Organization Control (SOC) 2 Type 2
- SOC 1 Type 2
- PCI DSS
- HIPAA
- HITECH
- NIST 800-53
- ISO 27001:2013
Location
West Jordan, UT 84088
West Valley City, UT 84128
What’s Inside
Cooling Infrastructure
Aligned’s flexible, efficient cooling technologies enable densities of 3 to 350 kW per rack.
Power Distribution
Flexible, modular equipment designed for hyper-scalability,
resiliency and 100% uptime
Sustainability
Ultra-efficient, rapidly deployable infrastructure with renewable power options
Operational Excellence
Customer-driven team,
offering remote hands assistance for enterprises
Customer Portal
Real-time visibility and control
of your infrastructure
Security and Compliance
Multi-layered physical security
and stringent data protection standards